Range of Controllers for Diesel Engine-Generator Sets and for Water Purification Plants

Product Name/Code INFOGEN: DG-CL-01 PROTOGEN: DG-CL-02 AQUATIK: AQ-CL-01
Functions Control and Protection of Diesel-Generator Sets-Two Versions Control and Protection of Diesel Generator Sets Sequence Controller and Monitor for RO Water Purification Plants
Analog Inputs 1 for Water Temperature, 1 Spare, 1 Each for Pressure, Exhaust Temperature, Fuel Level, MPU and Battery Voltage For Battery Voltage (5.5 to 32 V, DC)/td> 1 Each for Sensor for Temperature, ORP, 2 Each for pH, Conductivity and for Flow of Water.
Digital Inputs 7 Potential Free Contact 12 Potential Free Contact 6 Pressure Switches, 2 Level Switches
Digital Outputs 7 Relays 11 (Open Collector Relay Driving Contact), 36 V, 500 mA 13 Relays: Rating: 230 V, AC, 5A or 24V DC, 2A.
Electrical Parameters Line/Phase Voltage, Equivalent Current, PF, Active Energy, Individual Phase Current and PF, Frequency, Apparent Power and Energy, Reactive Power and Energy 3 Phase Mains/DG Voltage, 3 Phase Load Current, Individual PF, Active Power, DG, Mains KWH, Total KVA, Generator Speed, Fuel Consumed, Running Hours, Load KVA in %. 3 Phase Current and Voltage
Software Features Admin and Guest Mode, Start Failure, Engine Status, Alarm Acknowledge, Configurable i/p and o/p, Service Intervals, Sensor Diagnostics, Engine Crank Timing, Password Locking and AMF function. Run Mode: Auto/Manual; Program Mode: Set RTC, Fault/Data Log and Set Parameter; Fault/Data Mode: DG Log Event, Fault Log, Fuel Consumed DG/Mains KWH Log, GSM/CDMA compatible. Run Mode: Auto/Manual Flushing, Normal Working; Parameter Setting Mode: Calibration, Data Logging, Enable/Disable, Store Default, Test Limit Setting, Timer Setting, RTC Setting
Accuracy Class 1 Class 1 Overall 5 %
Refresh Time One Second One Second One Second
Data Logging Last Fifty Faults including Windows based software on Computer. Fuel Consumed, DG Log Events, DG KWH, Mains KWH, Running Hours, Total DG and Mains KWH, Storage (FIFO) with Date and Time. 100 Sets of Fault Data Storage with Date and Time in FIFO Mode.
Front Panel 7Keys, 2 LED on Fault Relay Activation, 2 Linex16 Character or 4-Line 29 Character LCD Display 7 Keys, 12 Mimic LED on Fault Alarm Relay Activation, 4 Linex20 Character LCD Display 6 Keys, Mimic Diagram with 26 LED for Process Indication and Blinking on Fault Relay Activation, 2 Linex16 Character LCD Display
Enclosure IP 55, MS/ABS, IP55, MS/ABS, IP 55, MS/ABS
Dimensions, mm 96 x 192 x 100 (H x W x D), DIN 96 x 192 x 100 (H x W x D), DIN 144 x 270 x 160 (H x W x D), DIN
Mounting Flush on Panel Flush on Panel Flush on Panel
Weight (Approximate) 700 gram 650 gram 900 gram
Energy Meter
Voice Logger