Protogen (DG-CL-01)


Control, Protection and AMF Controller for Diesel Generator Set

Click on image to enlarge
Protogen is a 3-phase Automatic/Manual Generator controller module including protection for DG sets. It is designed with an advanced single chip microcomputer for easy and trouble free DG set control in case of mains power failures. If mains power fails (due to Over/Under voltage, Unbalance, Single Phasing, Phase Reversal etc.), Protogen initiates an automatic DG set "start cycle" including load transfer to the Generator by switching on the Generator contactors. After the main power is restored, the load would get automatically transferred back to mains and the DG set would stop after "cool down" time.
Features:

It displays of four parameters of diesel engine and nineteen electrical parameters of DG set and Mains.

Records of 99 Faults of: (a) DG set and Mains with time and date, (b) DG-KWH (c) Mains-KWH with date, (d) Fuel Consumption with date and (e) DG Logging events with Date and Time. Retention of data is based on FIFO.

Twenty-nine programmable parameters for control, safety and test purposes

built-in RS-232 Communication Interface

Display of: (a) Generator Phase Rn,Yn, Bn voltages and Frequency, RPM (b) Mains Phase Rn, Yn, ,Bn Voltages, (c) Date and Time, (d) Mains and DG-KWH, (e) Power Factor R, Y, B, (f) DG Battery voltage, (g) Fault Log data, DG start/stop events.

built-in MIMIC Display


Optional Features:

GSM/CDMA Interface
Duplication of Data on other Unit


Power Supply:

Input 5.5 V-32 V, DC


Digital Input-12 Nos. (32 V DC max and Engine Ground.)

(a) Low Lube Oil Pressure Switch Input Input      (HWT) (b)High Coolant/Cylinder Temperature      Switch
(c) Low Fuel Switch Input (d) Emergency Stop Switch Input
(e) Auto/Manual Mode Switch Input (f) DG contactor ON Switch Input
(g) Fire Alarm Switch Input (h) Half Fuel Switch Input
(i) Canopy Temperature High Switch Input (j) Remote Start Switch Input
(k) Spare Switch Input (l) Spare Switch Input

LED Indications:

(a) Low Battery Voltage (b) Low Oil Pressure (c) High Temperature (d) Fail to Start (e) Fuel Level (f) Over Speed (g) Emergency Stop (h) Alarm (i) Mains (j) Mains Contactor (k) Generator (I) Generator Contactor


Digital Outputs for External Relay connections-11 Numbers for:

Open Collector Relay Driving Output: 36V, 500mA (Maximum) for:

(a) Engine Start Relay (b) Engine Stop Relay (c) Hooter Relay (d) Mains Contactor Relay (e) DG Contactor Relay (f) LLOP Relay (g) Mains Fail Relay (h) DG Common Fault Relay (i) Low Fuel Relay (j) Fire Alarm Relay (k) Engine Temperature Relay


Analog Input:

(A) Battery Voltage: 24 V, DC, (b) Three Phase Input Current: 0-5 Amps and (c) Mains and DG set Three Phase Input Voltage: 0-500 volts, AC


General Specifications:

Display Update time : One second
Display : Backlit, LCD 20X4 Line with 7 keys
Serial Port : One
Operating Temperature : 0°C to 55°C
Relative Humidity at 40° C : 0% to 95%, Non-condensing
Storage Temperature : -25°C to 70°C
Termination : Detachable, MKDS
Enclosure and Mounting : IP55, Panel Mounting or Wall Mounting- Optional
Dimensions (HXWXD) : 96x192x100 mm